REFERENCES

1. DeGowin EL, DeGowin RL: Bedside Diagnostic Examination, 5th ed. New York, Macmillan, 1987.

2. Bland JM, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1:307–310, 1986.

3. Sykes MK, Vickers MD, Hull CJ: Ultrasound. In Principles of Measurement and Monitoring in Anaesthesia and Intensive Care, 3rd ed. Oxford, Blackwell, 1991.

4. Beecher HK: The first anesthetic records (Cushing and Codman). Surg Gynecol Obstet 71:689–692, 1940.

5. Cushing H: Technical methods of performing certain cranial operations. Surg Gynecol Obstet 6:237–246, 1908.

6. Connors AF Jr, Speroff T, Dawson NV, et al: The effectiveness of right heart catheterization in the initial care of critically ill patients. JAMA 276:889–897, 1996.

7. Sandham JD, Hull RD, Brant RF, et al: A randomized, controlled trial of the use of pulmonary-artery catheters in high-risk surgical patients. N Engl J Med 348:5–14, 2003.

8. Quill TJ: Blood pressure monitoring. In Ehrenwerth J (ed): Anesthesia Equipment Principles and Applications. St Louis, Mosby-Year Book, 1993, p 274.

9. O'Brien E: Has conventional sphygmomanometry ended with the banning of mercury? Blood Press Monit 7:37–40, 2002.

10. Ireland J: In praise of mercury sphygmomanometers. Electronic readings of blood pressure seem to be higher than readings obtained with mercury sphygmomanometers. BMJ 322:1249, 2001.

11. Cicman JH, Gotzon J, Himmelwright C, et al: Operating Principles of Narkomed Anesthesia Systems, 2nd ed. Telford, PA, WE Andrews, 1998.

12. Q2 CCO/SvO2 Monitoring System Operating Manual [computer program]. North Chicago, Abbott Laboratories, 1998.

13. Szocik JF, Tremper K, Barker SJ: Fundamental principles of monitoring and instrumentation. In Miller RD (ed): Anesthesia, vol 1, 5th ed. San Francisco, Churchill Livingstone, 2000, pp 1053–1086.

14. Resnick R, Halliday D: Physics for Students of Science and Engineering. New York, John Wiley & Sons, 1960.

15. Rappaport MB, Sprague H: physiologic and physical laws that govern auscultation, and their clinical application. Am Heart J 21:257, 1941.

16. Cahalan MK, Litt L, Botvinick EH, Schiller NB: Advances in noninvasive cardiovascular imaging: Implications for the anesthesiologist. Anesthesiology 66:356–372, 1987.

17. Clements FM, de Bruijn NP: Perioperative evaluation of regional wall motion by transesophageal two-dimensional echocardiography. Anesth Analg 66:249–261, 1987.

18. Gravenstein JS, Paulus JS, Hayes TJ: Capnography in Clinical Practice. Boston, Butterworths, 1989.

19. Severinghaus JW, Astrup PB: History of blood gas analysis. Int Anesthesiol Clin 25:1–224, 1987.

20. Tremper KK, Barker SJ: Pulse oximetry. Anesthesiology Jan 70:98–108, 1989.

21. Barker SJ, Tremper KK, Hyatt J: Effects of methemoglobinemia on pulse oximetry and mixed venous oximetry. Anesthesiology 70:112–117, 1989.

22. Pologe JA: Pulse oximetry: Technical aspects of machine design. Int Anesthesiol Clin 25:137–153, 1987.

23. Dumas C, Wahr JA, Tremper KK: Clinical evaluation of a prototype motion artifact resistant pulse oximeter in the recovery room. Anesth Analg 83:269–272, 1996.

24. Barker SJ, Shah NK: The effects of motion on the performance of pulse oximeters in volunteers (revised publication). Anesthesiology 86:101–108, 1997.

25. Wahr JA, Tremper KK, Samra S, Delpy DT: Near-infrared spectroscopy: Theory and applications. J Cardiothorac Vasc Anesth 10:406–418, 1996.

26. Westenskow DR, Smith KW, Coleman DL, et al: Clinical evaluation of a Raman scattering multiple gas analyzer for the operating room. Anesthesiology 70:350–355, 1989.


1218


27. Budavari S, O'Neil MJ, Smith A, Heckelman P: The Merck Index, 11th ed. Rahway, NJ, Merck, 1989.

28. Moxham JP, Lee PK: Broken glass mercury thermometer: A difficult airway foreign body. Otolaryngol Head Neck Surg 127:339–341, 2002.

29. Shinozaki T, Deane R, Perkins FM: Infrared tympanic thermometer: Evaluation of a new clinical thermometer. Crit Care Med 16:148–150, 1988.

30. Pransky SM: The impact of technique and conditions of the tympanic membrane upon infrared tympanic thermometry. Clin Pediatr (Phila) 30(4 Suppl):50–52, discussion 60, 1991.

31. Terndrup TE, Rajk J: Impact of operator technique and device on infrared emission detection tympanic thermometry. J Emerg Med 10:683–687, 1992.

32. Chamberlain JM, Terndrup TE: New light on ear thermometer readings. Contemp Pediatr 11:66–76, 1994.

33. Vaughn MS, Cork RC, Vaughn RW: Inaccuracy of liquid crystal thermometry to identify core temperature trends in postoperative adults. Anesth Analg 61:284–287, 1982.

34. Ikeda T, Sessler DI, Marder D, Xiong J: Influence of thermoregulatory vasomotion and ambient temperature variation on the accuracy of core-temperature estimates by cutaneous liquid-crystal thermometers. Anesthesiology 86:603–612, 1997.