|
|
REFERENCES
1.
DeGowin EL, DeGowin RL: Bedside Diagnostic Examination,
5th ed. New York, Macmillan, 1987.
2.
Bland JM, Altman DG: Statistical methods for assessing
agreement between two methods of clinical measurement. Lancet 1:307–310, 1986.
3.
Sykes MK, Vickers MD, Hull CJ: Ultrasound. In
Principles of Measurement and Monitoring in Anaesthesia and Intensive Care, 3rd ed.
Oxford, Blackwell, 1991.
4.
Beecher HK: The first anesthetic records (Cushing
and Codman). Surg Gynecol Obstet 71:689–692, 1940.
5.
Cushing H: Technical methods of performing certain
cranial operations. Surg Gynecol Obstet 6:237–246, 1908.
6.
Connors AF Jr, Speroff T, Dawson NV, et al: The
effectiveness of right heart catheterization in the initial care of critically ill
patients. JAMA 276:889–897, 1996.
7.
Sandham JD, Hull RD, Brant RF, et al: A randomized,
controlled trial of the use of pulmonary-artery catheters in high-risk surgical patients.
N Engl J Med 348:5–14, 2003.
8.
Quill TJ: Blood pressure monitoring. In
Ehrenwerth J (ed): Anesthesia Equipment Principles and Applications. St Louis,
Mosby-Year Book, 1993, p 274.
9.
O'Brien E: Has conventional sphygmomanometry ended
with the banning of mercury? Blood Press Monit 7:37–40, 2002.
10.
Ireland J: In praise of mercury sphygmomanometers.
Electronic readings of blood pressure seem to be higher than readings obtained with
mercury sphygmomanometers. BMJ 322:1249, 2001.
11.
Cicman JH, Gotzon J, Himmelwright C, et al: Operating
Principles of Narkomed Anesthesia Systems, 2nd ed. Telford, PA, WE Andrews, 1998.
12.
Q2 CCO/SvO2 Monitoring System Operating Manual
[computer program]. North Chicago, Abbott Laboratories, 1998.
13.
Szocik JF, Tremper K, Barker SJ: Fundamental principles
of monitoring and instrumentation. In Miller RD (ed): Anesthesia, vol 1, 5th ed.
San Francisco, Churchill Livingstone, 2000, pp 1053–1086.
14.
Resnick R, Halliday D: Physics for Students of
Science and Engineering. New York, John Wiley & Sons, 1960.
15.
Rappaport MB, Sprague H: physiologic and physical
laws that govern auscultation, and their clinical application. Am Heart J 21:257,
1941.
16.
Cahalan MK, Litt L, Botvinick EH, Schiller NB:
Advances in noninvasive cardiovascular imaging: Implications for the anesthesiologist.
Anesthesiology 66:356–372, 1987.
17.
Clements FM, de Bruijn NP: Perioperative evaluation
of regional wall motion by transesophageal two-dimensional echocardiography. Anesth
Analg 66:249–261, 1987.
18.
Gravenstein JS, Paulus JS, Hayes TJ: Capnography
in Clinical Practice. Boston, Butterworths, 1989.
19.
Severinghaus JW, Astrup PB: History of blood gas
analysis. Int Anesthesiol Clin 25:1–224, 1987.
20.
Tremper KK, Barker SJ: Pulse oximetry. Anesthesiology
Jan 70:98–108, 1989.
21.
Barker SJ, Tremper KK, Hyatt J: Effects of methemoglobinemia
on pulse oximetry and mixed venous oximetry. Anesthesiology 70:112–117, 1989.
22.
Pologe JA: Pulse oximetry: Technical aspects
of machine design. Int Anesthesiol Clin 25:137–153, 1987.
23.
Dumas C, Wahr JA, Tremper KK: Clinical evaluation
of a prototype motion artifact resistant pulse oximeter in the recovery room. Anesth
Analg 83:269–272, 1996.
24.
Barker SJ, Shah NK: The effects of motion on the
performance of pulse oximeters in volunteers (revised publication). Anesthesiology
86:101–108, 1997.
25.
Wahr JA, Tremper KK, Samra S, Delpy DT: Near-infrared
spectroscopy: Theory and applications. J Cardiothorac Vasc Anesth 10:406–418,
1996.
26.
Westenskow DR, Smith KW, Coleman DL, et al: Clinical
evaluation of a Raman scattering multiple gas analyzer for the operating room. Anesthesiology
70:350–355, 1989.
27.
Budavari S, O'Neil MJ, Smith A, Heckelman P: The
Merck Index, 11th ed. Rahway, NJ, Merck, 1989.
28.
Moxham JP, Lee PK: Broken glass mercury thermometer:
A difficult airway foreign body. Otolaryngol Head Neck Surg 127:339–341,
2002.
29.
Shinozaki T, Deane R, Perkins FM: Infrared tympanic
thermometer: Evaluation of a new clinical thermometer. Crit Care Med 16:148–150,
1988.
30.
Pransky SM: The impact of technique and conditions
of the tympanic membrane upon infrared tympanic thermometry. Clin Pediatr (Phila)
30(4 Suppl):50–52, discussion 60, 1991.
31.
Terndrup TE, Rajk J: Impact of operator technique
and device on infrared emission detection tympanic thermometry. J Emerg Med 10:683–687,
1992.
32.
Chamberlain JM, Terndrup TE: New light on ear
thermometer readings. Contemp Pediatr 11:66–76, 1994.
33.
Vaughn MS, Cork RC, Vaughn RW: Inaccuracy of liquid
crystal thermometry to identify core temperature trends in postoperative adults.
Anesth Analg 61:284–287, 1982.
34.
Ikeda T, Sessler DI, Marder D, Xiong J: Influence
of thermoregulatory vasomotion and ambient temperature variation on the accuracy
of core-temperature estimates by cutaneous liquid-crystal thermometers. Anesthesiology
86:603–612, 1997.