REFERENCES
451.
Morris AH, Chapman RH, Gardner RM: Frequency
of technical problems encountered in the measurement of pulmonary artery wedge pressure.
Crit Care Med 12:164–170, 1984.
452.
Schmitt EA, Brantigan CO: Common artifacts of
pulmonary artery and pulmonary artery wedge pressures: Recognition and interpretation.
J Clin Monit 2:44–52, 1986.
453.
Bashein G: Another source of artifact in the
pulmonary artery pressure waveform. Anesthesiology 68:310, 1988.
454.
Sharkey SW: Beyond the wedge: Clinical physiology
and the Swan-Ganz catheter. Am J Med 83:111–122, 1987.
455.
Dobson GM, Horan BF, Bradburn NT: Significance
of diastolic pulmonary artery pressure peaks. J Clin Monit 8:62–65, 1992.
456.
Bethea CF, Peter RH, Behar VS, et al: The hemodynamic
simulation of mitral regurgitation in ventricular septal defect after myocardial
infarction. Cathet Cardiovasc Diagn 2:97–104, 1976.
457.
Fuchs RM, Heuser RR, Yin FCP, Brinker JA: Limitations
of pulmonary wedge V waves in diagnosing mitral regurgitation. Am J Cardiol 49:849–854,
1982.
458.
Grossman W: Profiles in valvular heart disease.
In Grossman W, Baim DS (eds): Cardiac Catheterization,
Angiography, and Intervention. Philadelphia, Lea & Febiger, 1991, pp 557–581.
459.
Pichard AD, Kay R, Smith H, et al: Large V waves
in the pulmonary wedge pressure tracing in the absence of mitral regurgitation.
Am J Cardiol 50:1044–1050, 1982.
460.
Snyder RW, Glamann DB, Lange RA, et al: Predictive
value of prominent pulmonary arterial wedge V waves in assessing the presence and
severity of mitral regurgitation. Am J Cardiol 73:568–570, 1994.
461.
Royster RL, Johnson JC, Prough DS, et al: Differences
in pulmonary artery wedge pressures obtained by balloon inflation versus impaction
techniques. Anesthesiology 61:339–341, 1984.
462.
Braunwald E, Awe WC: The syndrome of severe mitral
regurgitation with normal left atrial pressure. Circulation 27:29–35, 1963.
463.
Velky PJ, Harte FA: The appearance of large "V"
waves in association with sternal retraction during coronary artery surgery. J Cardiothorac
Vasc Anesth 6:453–455, 1992.
464.
Bourdillon PD, Lorell BH, Mirsky I, et al: Increased
regional myocardial stiffness of the left ventricle during pacing-induced angina
in man. Circulation 67:316–323, 1983.
465.
Dodek A, Kassebaum DG, Bristow JD: Pulmonary
edema in coronary-artery disease without cardiomegaly. Paradox of the stiff heart.
N Engl J Med 286:1347–1350, 1972.
466.
Grossman W: Diastolic dysfunction in congestive
heart failure. N Engl J Med 325:1557–1564, 1991.
467.
Mark JB: Myocardial ischemia. Hemodynamic detection.
In Mark JB (ed): Atlas of Cardiovascular Monitoring.
New York, Churchill Livingstone, 1998, pp 181–204.
468.
McLaurin LP, Rolett EL, Grossman W: Impaired
left ventricular relaxation during pacing-induced ischemia. Am J Cardiol 32:751–757,
1973.
469.
Waters DD, da Luz P, Wyatt HL, et al: Early changes
in regional and global left ventricular function induced by graded reductions in
regional coronary perfusion. Am J Cardiol 39:537–543, 1977.
470.
Attia RR, Murphy JD, Snider M, et al: Myocardial
ischemia due to infrarenal aortic cross-clamping during aortic surgery in patients
with severe coronary artery disease. Circulation 53:961–965, 1976.
471.
Haggmark S, Hohner P, Ostman M, et al: Comparison
of hemodynamic, electrocardiographic, mechanical, and metabolic indicators of intraoperative
myocardial ischemia in vascular surgical patients with coronary artery disease.
Anesthesiology 70:19–25, 1989.
472.
Kaplan JA, Wells PH: Early diagnosis of myocardial
ischemia using the pulmonary arterial catheter. Anesth Analg 60:789–793, 1981.
473.
Kaplan JA: Indications for pulmonary arterial
catheterization. Anesth Analg 61:477–479, 1982.
474.
Rahimtoola SH, Loeb HS, Ehsani A, et al: Relationship
of pulmonary artery to left ventricular diastolic pressures in acute myocardial infarction.
Circulation 46:283–290, 1972.
475.
Sanchez R, Wee M: Perioperative myocardial ischemia:
Early diagnosis using the pulmonary artery catheter. J Cardiothorac Vasc Anesth
5:604–607, 1991.
476.
van Daele MERM, Sutherland GR, Mitchell MM, et
al: Do changes in pulmonary capillary wedge pressure adequately reflect myocardial
ischemia during anesthesia: A correlative preoperative hemodynamic, electrocardiographic,
and transesophageal echocardiographic study. Circulation 81:865–871, 1990.
477.
Stott DK, Marpole DGF, Bristow JD, et al: The
role of left atrial transport in aortic and mitral stenosis. Circulation 41:1031–1041,
1970.
478.
Wohlgelernter D, Jaffe CC, Cabin HS, et al: Silent
ischemia during coronary occlusion produced by balloon inflation: Relation to regional
myocardial dysfunction. J Am Coll Cardiol 10:491–498, 1978.
479.
Leung JM, O'Kelly BF, Mangano DT: Relationship
of regional wall motion abnormalities to hemodynamic indices of myocardial oxygen
supply and demand in patients undergoing CABG surgery. Anesthesiology 73:802–814,
1990.
480.
Slogoff S, Keats AS: Does perioperative myocardial
ischemia lead to postoperative myocardial infarction? Anesthesiology 62:107–114,
1985.
481.
Slogoff S, Keats AS: Further observations on
perioperative myocardial ischemia. Anesthesiology 65:539–542, 1986.
482.
Sabbah HN, Rosman H, Kono T, et al: On the mechanism
of functional mitral regurgitation. Am J Cardiol 72:1074–1076, 1993.
483.
Longabaugh JP, Sheikh KH, Bengtson JR, et al:
Diagnosis and management of ischemic mitral regurgitation with the use of transesophageal
echocardiography. Coronary Artery Dis 3:377–381, 1992.
484.
Bashein G, Ivey TD: Con: A pulmonary artery
catheter is not indicated for all coronary artery surgery. J Cardiothorac Anesth
1:362–365, 1987.
485.
Keats AS: Adventures in perioperative myocardial
ischemia. Tex Heart Inst J 20:5–11, 1993.
486.
Lieberman RW, Orkin FK, Jobes DR, Schwartz AJ:
Hemodynamic predictors of myocardial ischemia during halothane anesthesia for coronary-artery
revascularization. Anesthesiology 59:36–41, 1983.
487.
Weintraub AC, Barash PG: A pulmonary artery catheter
is indicated in all patients for coronary artery surgery. J Cardiothorac Anesth
1:358–361, 1987.
488.
Wickey GS, Larach DR, Keifer JC, et al: Combined
interpretation of transesophageal echocardiography, electrocardiography, and pulmonary
artery wedge waveform to detect myocardial ischemia. J Cardiothorac Anesth 4:102–104,
1990.
489.
Lorell B, Leinbach RC, Pohost GM, et al: Right
ventricular infarction. Clinical diagnosis and differentiation from cardiac tamponade
and pericardial constriction. Am J Cardiol 43:465–471, 1979.
490.
Goldstein JA, Barzilai B, Rosamond TL, et al:
Determinants of hemodynamic compromise with severe right ventricular infarction.
Circulation 82:359–368, 1990.
491.
Kushwaha SS, Fallon JT, Fuster V: Restrictive
cardiomyopathy. N Engl J Med 336:267–276, 1997.
492.
Kern MJ, Aguirre F: Interpretation of cardiac
pathophysiology from pressure waveform analysis: Pericardial compressive hemodynamics,
part I. Cathet Cardiovasc Diagn 25:336–342, 1992.
493.
Kern MJ, Aguirre F: Interpretation of cardiac
pathophysiology from pressure waveform analysis: Pericardial compressive hemodynamics,
part II. Cathet Cardiovasc Diagn 26:34–40, 1992.
494.
Kern MJ, Aguirre F: Interpretation of cardiac
pathophysiology from pressure waveform analysis: Pericardial compressive hemodynamics,
part III. Cathet Cardiovasc Diagn 26:152–158, 1992.
495.
Hirschmann JV: Pericardial constriction. Am
Heart J 96:110–122, 1978.
496.
Beloucif S, Takata M, Shimada M, Robotham JL:
Influence of pericardial constraint on atrioventricular interactions. Am J Physiol
263:H125–H134, 1992.
497.
Greenberg MA, Gitler B: Left ventricular rupture
in a patient with coexisting right ventricular infarction. N Engl J Med 309:539–542,
1983.
498.
Lorell BH, Braunwald E: Pericardial disease.
In Braunwald E (ed): Heart Disease. A Textbook
of Cardiovascular Medicine, 4th ed. Philadelphia, WB Saunders, 1992, pp 1465–1516.
499.
Fowler NO: Cardiac tamponade. A clinical or
an echocardiographic diagnosis? Circulation 87:1738–1741, 1993.
500.
Hancock EW: Subacute effusive-constrictive pericarditis.
Circulation 43:183–192, 1971.
501.
Ellis DM: Interpretation of beat-to-beat blood
pressure values in the presence of ventilatory changes. J Clin Monit 1:65–70,
1985.
502.
Hoeksel SAAP, Blom JA, Jansen JRC, Schreuder JJ:
Correction for respiration artifact in pulmonary blood pressure signals of ventilated
patients. J Clin Monit 12:397–403, 1996.
503.
Mitchell MM, Meathe EA, Jones BR, et al: Accurate,
automated, continuously displayed pulmonary artery pressure measurement. Anesthesiology
67:294–300, 1987.
504.
Teplick RS: Measuring central vascular pressures:
A surprisingly complex problem. Anesthesiology 67:289–291, 1987.
505.
Cengiz M, Crapo RO, Gardner RM: The effect of
ventilation on the accuracy of pulmonary artery and wedge pressure measurements.
Crit Care Med 11:502–507, 1983.
506.
Bell H, Stubbs D, Pugh D: Reliability of central
venous pressure as an indicator of left atrial pressure. A study in patients with
mitral valve disease. Chest 59:169–173, 1971.
507.
Buchbinder N, Ganz W: Hemodynamic monitoring:
Invasive techniques. Anesthesiology 45:146–155, 1976.
508.
Cohn JN, Tristani FE, Khatri IM: Relationship
between left and right ventricular function. J Clin Invest 48:2008–2018, 1969.
509.
Toussaint GPM, Burgess JH, Hampson LG: Central
venous pressure and pulmonary wedge pressure in critical surgical illness. A comparison.
Arch Surg 109:265–269, 1974.
510.
Mangano DT: Monitoring pulmonary arterial pressure
in coronary-artery disease. Anesthesiology 53:364–370, 1980.
511.
Lowenstein E, Teplick R: To (PA) catheterize
or not to (PA) catheterize—that is the question. Anesthesiology 53:361–363,
1980.
512.
Tuman KJ, Carroll GC, Ivankovich AD: Pitfalls
in interpretation of pulmonary artery catheter data. J Cardiothorac Anesth 3:625–641,
1989.
513.
Mark JB: Predicting left ventricular end-diastolic
pressure. In Mark JB (ed): Atlas of Cardiovascular
Monitoring. New York, Churchill Livingstone, 1998, pp 59–79.
514.
Mitchell JH, Gilmore JP, Sarnoff SJ: The transport
function of the atrium. Factors influencing the relation between mean left atrial
pressure and left ventricular end diastolic pressure. Am J Cardiol 9:237–247,
1962.
515.
Herbert WH: Left ventricular compliance and pulmonary
artery end-diastolic pressure. N Y State J Med 77:344–348, 1977.
516.
Herbert WH: Pulmonary artery and left heart end-diastolic
pressure relations. Br Heart J 32:774–778, 1970.
517.
Berry AJ, Geer RT, Marshall BE: Alteration of
pulmonary blood flow by pulmonary-artery occluded pressure measurement. Anesthesiology
51:164–166, 1979.
518.
Wittnich C, Trudel J, Zidulka A, Chiu RC: Misleading
"pulmonary wedge pressure" after pneumonectomy: Its importance in postoperative
fluid therapy. Ann Thorac Surg 42:192–196, 1986.
519.
Berryhill RE, Benumof JL: PEEP-induced discrepancy
between pulmonary arterial wedge pressure and left atrial pressure: The effects
of controlled vs. spontaneous ventilation and compliant vs. noncompliant lungs in
the dog. Anesthesiology 51:303–308, 1979.
520.
Guyton RA, Chiavarelli M, Padgett CA, et al:
The influence of positive end-expiratory pressure on intrapericardial pressure and
cardiac function after coronary artery bypass surgery. J Cardiothorac Anesth 1:98–107,
1987.
521.
Nadeau S, Noble WH: Misinterpretation of pressure
measurements from the pulmonary artery catheter. Can Anaesth Soc J 33:352–363,
1986.
522.
Pinsky M, Vincent J-L, De Smet J-M: Estimating
left ventricular filling pressure during positive end-expiratory pressure in humans.
Am Rev Respir Dis 143:25–31, 1991.
523.
Teboul JL, Zapol WM, Brun-Buisson C, et al: A
comparison of pulmonary artery occlusion pressure and left ventricular end-diastolic
pressure during mechanical ventilation with PEEP in patients with severe ARDS. Anesthesiology
70:261–266, 1989.
524.
Cozzi PJ, Hall JB, Schmidt GA: Pulmonary artery
diastolic-occlusion pressure gradient is increased in acute pulmonary embolism.
Crit Care Med 23:1481–1484, 1995.
525.
Case Records of the Massachusetts General Hospital
(Case 21-1986). N Engl J Med 314:1435–1445, 1986.
526.
Case records of the Massachusetts General Hospital
(Case 48-1993). N Engl J Med 329:1720–1728, 1993.
527.
Kern MJ, Aguirre FV: Mitral valve gradients:
Part I. In Kern MJ (ed): Hemodynamic Rounds.
Interpretation of Cardiac Pathophysiology from Pressure Waveform Analysis. New York,
Wiley-Liss, 1993, pp 35–42.
528.
Enson Y, Wood JA, Mantaras NB, Harvey RM: The
influence of heart rate on pulmonary arterial-left ventricular pressure relationships
at end-diastole. Circulation 56:533–539, 1977.
529.
Dalen JE, Bone RC: Is it time to pull the pulmonary
artery catheter? JAMA 276:916–918, 1996.
530.
Soni N: Swan song for the Swan-Ganz catheter?
The use of pulmonary artery catheters probably needs re-evaluation—but they
should not be banned. BMJ 313:763–764, 1996.
531.
Prielipp RC, Morell R: Con: Swan song for the
Swan-Ganz? J Clin Monit 313:339–340, 1997.
532.
Tuman KJ: Pro: A moratorium on PAC is unjustified.
J Clin Monit 13:337–338, 1997.
533.
Robin ED: The cult of the Swan-Ganz catheter.
Intensive Crit Care Dig 5:18–21, 1986.
534.
Robin ED: Death by pulmonary artery flow-directed
catheter [editorial]. Time for a moratorium? Chest 92:727–731, 1987.
535.
Shoemaker WC: Use and abuse of the balloon tip
pulmonary artery (Swan-Ganz) catheter: Are patients getting their money's worth?
Crit Care Med 18:1294–1296, 1990.
536.
MacDonald D: Cerebral palsy and intrapartum fetal
monitoring. N Engl J Med 334:659–660, 1996.
537.
Nelson KB, Dambrosia JM, Ting TY, Grether JK:
Uncertain value of electronic fetal monitoring in predicting cerebral palsy. N
Engl J Med 334:613–618, 1996.
538.
Shy KK, Luthy DA, Bennett FC, et al: Effects
of electronic fetal-heart-rate monitoring, as compared with periodic auscultation,
on the neurologic development of premature infants. N Engl J Med 322:588–593,
1990.
539.
Cooper AB, Doig GS, Sibbald WJ: Pulmonary artery
catheters in the critically ill. An overview using the methodology of evidence-based
medicine. Crit Care Clin 12:777–794, 1996.
540.
Berlauk J, Abrams JH, Gilmour IJ, et al: Preoperative
optimization of cardiovascular hemodynamics improves outcome in peripheral vascular
surgery. A prospective, randomized clinical trial. Ann Surg 214:289–299,
1991.
541.
Del Guercio LRM, Cohn JD: Monitoring operative
risk in the elderly. JAMA 243:1350–1355, 1980.
542.
Flancbaum L, Ziegler DW, Choban PS: Preoperative
intensive care unit admission and hemodynamic monitoring in patients scheduled for
major elective noncardiac surgery: A retrospective review of 95 patients. J Cardiothorac
Vasc Anesth 12:3–9, 1998.
543.
Moore CH, Lombardo R, Allums JA, Gordon FT: Left
main coronary artery stenosis: Hemodynamic monitoring to reduce mortality. Ann
Thorac Surg 26:445–451, 1978.
544.
Scalea TM, Simon HM, Duncan AO, et al: Geriatric
blunt multiple trauma: Improved survival with early invasive monitoring. J Trauma
30:129–136, 1990.
545.
Tuchschmidt J, Fried J, Astiz M, Rackow E: Elevation
of cardiac output and oxygen delivery improves outcome in septic shock. Chest 102:216–220,
1992.
546.
Bender JS, Smith-Meek MA, Jones CE: Routine pulmonary
artery catheterization does not reduce morbidity and mortality of elective vascular
surgery. Ann Surg 226:229–237, 1997.
547.
Afessa B, Tefferi A, Hoagland HC, et al: Outcome
of recipients of bone marrow transplants who require intensive-care unit support.
Mayo Clin Proc 67:117–122, 1992.
548.
Isaacson IJ, Lowdon JD, Berry AJ, et al: The
value of pulmonary artery and central venous monitoring in patients undergoing abdominal
aortic reconstructive surgery: A comparative study of two selected, randomized groups.
J Vasc Surg 12:754–760, 1991.
549.
Pearson KS, Gomez MN, Moyers JR, et al: A cost/benefit
analysis of randomized invasive monitoring for patients undergoing cardiac surgery.
Anesth Analg 69:336–341, 1989.
550.
Rhodes A, Cusack RJ, Newman PJ, et al: A randomised,
controlled trial of the pulmonary artery catheter in critically ill patients. Intensive
Care Med 28:256–264, 2002.
551.
Richard C, Warszawski J, Anguel N, et al: Early
use of the pulmonary artery catheter and outcomes in patients with shock and acute
respiratory distress syndrome. A randomized controlled trial. JAMA 290:2713–2720,
2003.
552.
Dalen JE: The pulmonary artery catheter—friend,
foe, or accomplice? JAMA 286:348–350, 2001.
553.
Rao TLK, Jacobs KH, El-Etr AA: Reinfarction following
anesthesia in patients with myocardial infarction. Anesthesiology 59:499–505,
1983.
554.
Gore JM, Goldberg RJ, Spodick DH, et al: A community-wide
assessment of the use of pulmonary artery catheters in patients with acute myocardial
infarction. Chest 92:721–727, 1987.
555.
Zion MM, Balkin J, Rosenmann D, et al: Use of
pulmonary artery catheters in patients with acute myocardial infarction: Analysis
of experience in 5,841 patients in the SPRINT Registry. Chest 98:1331–1335,
1990.
556.
Bashein G, Johnson PW, Davis KB, Ivey TD: Elective
coronary bypass surgery without pulmonary artery catheter monitoring. Anesthesiology
63:451–454, 1985.
557.
Tuman KJ, McCarthy RJ, Spiess BD, et al: Effect
of pulmonary artery catheterization on outcome in patients undergoing coronary artery
surgery. Anesthesiology 70:199–206, 1989.
558.
Saarela E, Kari A, Nikki P, et al: Current practice
regarding invasive monitoring in intensive care units in Finland. Intensive Care
Med 17:264–271, 1991.
559.
Pulmonary Artery Catheter Consensus Conference
Participants: Pulmonary artery catheter consensus conference: Consensus statement.
Crit Care Med 25:910–925, 1997.
560.
Sibbald WJ, Keenan SP: Show me the evidence:
A critical appraisal of the Pulmonary Artery Catheter Consensus Conference and other
musings on how critical care practitioners need to improve the way we conduct business.
Crit Care Med 25:2060–2063, 1997.
561.
Knaus WA, Harrell FEJ, Lynn J, et al: The SUPPORT
prognostic model. Objective estimates of survival for seriously ill hospitalized
adults. Ann Intern Med 122:191–203, 1995.
562.
Lo B: Improving care near the end of life: Why
is it so hard? JAMA 274:1634–1635, 1995.
563.
Mark JB: Pulmonary artery catheterization wither.
Cardiovasc Thorac Anesth J Club J 2:8–9, 1997.
564.
SUPPORT Principal Investigators: A controlled
trial to improve care for seriously ill hospitalized patients. JAMA 274:1591–1598,
1995.
565.
Chernow B: Pulmonary artery flotation catheters.
Chest 111:261–262, 1997.
566.
Fowler RA, Cook DJ: The arc of the pulmonary
artery catheter. JAMA 290:2732–2734, 2003.
567.
Raoport J, Teres D, Steingrub J, et al: Patient
characteristics and ICU organizational factors that influence frequency of pulmonary
artery catheterization. JAMA 283:2559–2567, 2000.
568.
Ramsey SD, Saint S, Sullivan SD, et al: Clinical
and economic effects of pulmonary artery catheterization in nonemergent coronary
artery bypass graft surgery. J Cardiothorac Vasc Anesth 14:113–118, 2000.
569.
Shoemaker WC, Kram HB, Appel PL, Fleming AW:
The efficacy of central venous and pulmonary artery catheters and therapy based upon
them in reducing mortality and morbidity. Arch Surg 125:1332–1338, 1990.
570.
Shoemaker WC, Belzberg H: Pulmonary Artery Catheter
Consensus Conference. Crit Care Med 26:1760–1761, 1998.
571.
Pölönen, P, Ruokonen E, Hippeläinen
M, et al: A prospective, randomized study of goal-oriented hemodynamic therapy in
cardiac surgical patients. Anesth Analg 90:1052–1059, 2000.
572.
Rivers E, Nguyen B, Havstad S, et al: Early goal-directed
therapy in the treatment of severe sepsis and septic shock. N Engl J Med 345:1368–1377,
2001.
573.
Evans TW: Hemodynamic and metabolic therapy in
critically ill patients. N Engl J Med 345:1417–1418, 2001.
574.
Shoemaker WC, Thangathurai D, Wo CCJ, et al:
Intraoperative evaluation of tissue perfusion in high-risk patients by invasive and
noninvasive hemodynamic monitoring. Crit Care Med 27:2147–2152, 1999.
575.
Boyd O, Grounds RM, Bennett ED: A randomized
clinical trial of the effect of deliberate perioperative increase of oxygen delivery
on mortality in high-risk surgical patients. JAMA 270:2699–2707, 1993.
576.
Boyd O, Bennett ED: Achieving the goal. Crit
Care Med 27:2298–2299, 1999.
577.
Treasure T, Bennett D: Reducing the risk of major
elective surgery. BMJ 318:1087–1088, 1999.
578.
Wilson J, Woods I, Fawcett J, et al: Reducing
the risk of major elective surgery: Randomised controlled trial of preoperative
optimisation of oxygen delivery. BMJ 318:1099–1103, 1999.
579.
Gattinoni L, Brazzi L, Pelosi P, et al: A trial
of goal-oriented hemodynamic therapy in critically ill patients. N Engl J Med 333:1025–1032,
1995.
580.
Hayes MA, Timmins AC, Yau EHS, et al: Elevation
of systemic oxygen delivery in the treatment of critically ill patients. N Engl
J Med 330:1717–1722, 1994.
581.
Gasman JD, Ruoss SJ, Fishman RS, et al: Hazards
with both determining and utilizing oxygen consumption measurements in the management
of critically ill patients. Crit Care Med 24:6–9, 1996.
582.
Heyland DK, Cook DJ, King D, et al: Maximizing
oxygen delivery in critically ill patients: A methodologic appraisal of the evidence.
Crit Care Med 24:517–524, 1996.
583.
Hinds C, Watson D: Manipulating hemodynamics
and oxygen transport in critically ill patients. N Engl J Med 333:1074–1075,
1995.
584.
American College of Physicians/American College
of Cardiology/American Heart Association Task Force on Clinical Privileges in Cardiology:
Clinical competence in hemodynamic monitoring. J Am Coll Cardiol 15:1460–1464,
1990.
585.
Naylor CD, Sibbald WJ, Sprung CL, et al: Pulmonary
artery catheterization: Can there be an integrated strategy for guideline development
and research promotion? JAMA 269:2407–2411, 1993.
586.
Hemodynamic monitoring: A technology assessment.
Technology Subcommittee of the Working Group on Critical Care, Ontario Ministry
of Health. Can Med Assoc J 145:114–121, 1991.
587.
Keats AS: The Rovenstine lecture, 1983: Cardiovascular
anesthesia: Perceptions and perspectives. Anesthesiology 60:467–474, 1984.
588.
Sandham JD, Hull RD, Brant RF: Ethics of technology
assessment: Pulmonary artery flow directed catheter revisited. Am J Respir Crit
Care Med 153:A422, 1996.
589.
Sandham JD, Hull RD, Brant RF: Effect of the
pulmonary artery catheter on morbidity and mortality, a multicenter trial. Am J
Respir Crit Care Med 153:A601, 1996.
590.
Sandham JD, Hull RD, Brant RF: Pulmonary artery
flow directed catheter: The evidence. Lancet 348:1324, 1996.
591.
Sandham JD, Hull RD, Brant RF: The pulmonary
artery catheter takes a great fall. Crit Care Med 26:1288–1289, 1998.
592.
Spodick DH: Analysis of flow-directed pulmonary
artery catheterization. JAMA 261:1946–1947, 1989.
593.
Spodick DH: Effectiveness of right heart catheterization:
Time for a randomized trial. JAMA 277:113, 1997.
594.
Guyatt G: A randomized control trial of right-heart
catheterization in critically ill patients. Ontario Intensive Care Study Group.
J Intensive Care Med 6:91–95, 1991.
595.
Hall JB: Use of the pulmonary artery catheter
in critically ill patients. Was invention the mother of necessity? JAMA 283:2577–2578,
2000.
596.
Parsons PE: Progress in research on pulmonary-artery
catheters. N Engl J Med 348:66–68, 2003.
597.
Zaidan JR, Freniere S: Use of a pacing pulmonary
artery catheter during cardiac surgery. Ann Thorac Surg 35:633–636, 1983.
598.
Mora CT, Seltzer JL, McNulty SE: Evaluation of
a new design pulmonary artery catheter for intraoperative ventricular pacing. J
Cardiothorac Anesth 2:303–308, 1988.
599.
Trankina MF, White RD: Perioperative cardiac
pacing using an atrioventricular pacing pulmonary artery catheter. J Cardiothorac
Anesth 3:154–162, 1989.
600.
Teboul J-L: Dynamic concepts of volume responsiveness.
Int J Intensive Care 10:XX–YY, 2003.