|
|
REFERENCES
151.
Rampil IJ: A primer for EEG signal processing
in anesthesia. Anesthesiology 89:980, 1998.
152.
Sigl JC, Chamoun NG: An introduction to bispectral
analysis for the electroencephalogram. J Clin Monit 10:392, 1994.
153.
Kearse LA Jr, Manberg P, Chamoun N, et al: Bispectral
analysis of the electroencephalogram correlates with patient movement to skin incision
during propofol/nitrous oxide anesthesia. Anesthesiology 81:1365, 1994.
154.
Vernon JM, Lang E, Sebel PS, Manberg P: Prediction
of movement using bi-spectral EEG during propofol/alfentanil or isoflurane/alfentanil
anesthesia. Anesth Analg 80:780, 1995.
155.
Sebel PS, Lang E, Rampil IJ, et al: A multicenter
study of bispectral electroencephalogram analysis for monitoring anesthetic effect.
Anesth Analg 84:891, 1997.
156.
Glass PS, Bloom M, Kearse L, et al: Bispectral
analysis measures sedation and memory effects of propofol, midazolam, isoflurane
and alfentanil in healthy volunteers. Anesthesiology 86:836, 1997.
157.
Liu J, Singh H, White PF: Electroencephalogram
bispectral analysis predicts the depth of midazolam-induced sedation. Anesthesiology
84:64, 1996.
158.
Liu, J, Singh H, White PF: Electroencephalographic
bispectral index correlates with intraoperative recall and depth of propofol-induced
sedation. Anesth Analg 84:185, 1997.
159.
Katoh T, Suzuki A, Ikeda K: Electroencephalographic
derivatives as a tool for predicting the depth of sedation and anesthesia induced
by sevoflurane. Anesthesiology 88:642, 1998.
160.
Flaishon R, Windsor A, Sigl J, et al: Recovery
of consciousness after thiopental or propofol: Bispectral index and the isolated
forearm technique. Anesthesiology 86:613, 1997.
161.
Kearse LA, Rosow C, Zaslavsky A, et al: Bispectral
analysis of the electroencephalogram predicts conscious processing of information
during propofol sedation and hypnosis. Anesthesiology 88:25, 1998.
162.
Johansen JW, Sebel PS: Development and clinical
application of electroencephalographic bispectrum monitoring. Anesthesiology 93:1336,
2000.
163.
Alkire M: Quantitative EEG correlations with
brain glucose metabolic rate during anesthesia in volunteers. Anesthesiology 89:323,
1998.
164.
Ludbrook GL, Visco E, Lam AM: Propofol: Relation
between brain concentrations, electroencephalogram, middle cerebral blood flow velocity
and cerebral oxygen extraction during induction of anesthesia. Anesthesiology 97:1363,
2002.
165.
Iselin-Chaves IA, Flaishon R, Sebel PS, et al:
The effect of the interaction of propofol and alfentanil on recall, loss of consciousness
and the bispectral index. Anesth Analg 87:949, 1998.
166.
Guignard B, Menigaux C, Dupont X, et al: The
effect of remifentanil on the bispectral index change and hemodynamic response after
orotracheal intubation. Anesth Analg 90:161, 2000.
167.
Ropcke H, Rehberg B, Koennen-Bergmann M, et al:
Surgical stimulation shifts EEG concentration-response relationship with desflurane.
Anesthesiology 94:390, 2001.
168.
Rampil IJ, Kim JS, Lenhardt R, et al: Bispectral
EEG index during nitrous oxide administration. Anesthesiology 89:671, 1998.
169.
Coste C, Guignard B, Menigaux C, Chauvin M: Nitrous
oxide prevents movement during orotracheal intubation without affecting BIS value.
Anesth Analg 91:130, 2000.
170.
Katoh T, Bito H, Sato S: Influence of age on
hypnotic requirement, bispectral index, and 95% spectral edge frequency associated
with sedation by sevoflurane. Anesthesiology 92:55, 2000.
171.
Mathew JP, Weathersax KJ, East CJ, et al: Bispectral
analysis during cardiopulmonary bypass: The effect of hypothermia on the hypnotic
state. J Clin Anesth 13:301, 2001.
172.
Lopez M, Ozaki M, Sessler D, et al: Mild core
hyperthermia does not alter the electroencephalographic responses during epidural-enflurane
anesthesia in humans. J Clin Anesth 5:425, 1993.
173.
Johansen JW: Esmolol promotes electroencephalographic
burst suppression during propofol/alfentanil anesthesia. Anesth Analg 93:1526, 2001.
174.
Menigaux C, Guignard B, Adam F, et al: Esmolol
prevents movement and attenuates the BIS response to orotracheal intubation. Br
J Anaesth 89:857, 2002.
175.
Hodgson PS, Liu SS: Epidural lidocaine decreases
sevoflurane requirement for adequate depth of anesthesia as measured by the bispectral
index monitor. Anesthesiology 94:799, 2001.
176.
Morioka N, Ozaki M, Matsukawa T, et al: Ketamine
causes a paradoxical increase in the bispectral index. Anesthesiology 87:A502, 1997.
177.
Sakai T, Singh WD, Kudo T, et al: The effect
of ketamine on clinical endopoints of hypnosis and EEG variables during propofol
infusion. Acta Anaesthiol Scand 43:212, 1999.
178.
Gan TJ, Glass PS, Windsor A, et al: Bispectral
index monitoring allows faster emergence and improved recovery from propofol, alfentanil
and nitrous oxide anesthesia. Anesthesiology 87:808, 1997.
179.
Song D, Joshi GP, White PF: Titration of volatile
anesthetics using bi-spectral index facilitates recovery after ambulatory anesthesia.
Anesthesiology 87:842, 1997.
180.
Myles PS, Leslie K, McNeil J, Chan MTV, and the
B-Aware Trial Group: Bispectral index monitoring to prevent awareness during anaesthesia:
The B-Aware Randomized Controlled Trial. Lancet 363:1747–1757, 2004.
181.
Sebel PS, Bowdle A, Ghoneim M, et al: The incidence
of awareness during anesthesia: A multicenter US study. Anesthesiology 99:A-360,
2003.
182.
Lennmarken C, Ekman A, Sandin R: Incidence of
awareness using BIS-monitoring. Anesth Analg 96:S133, 2003.
183.
Weldon BC, Mahla ME, van der Aa M, et al: Advancing
age and deeper intraoperative anesthetic levels are associated with higher first
year death rates. Anesthesiology 97:A-1097, 2002.
184.
Lennmarken C, Lindholm MJ, Greenwald SC, et al:
Confirmation that low intraoperative BIS levels predict increased risk of post-operative
mortality. Anesthesiology 99:A-303, 2003.
185.
Monk T, Sigl J, Weldon BC: Intraoperative BIS
utilization is associated with reduced one-year post-operative mortality. Anesthesiology
99:A-1361, 2003.
186.
Grundy BL: Evoked potential monitoring. In
Blitt ED (ed): Monitoring in Anesthesia and Critical Care Medicine. New York, Churchill
Livingstone, 1985, p 345.
187.
Grundy BL: Intraoperative monitoring of sensory-evoked
potentials. Anesthesiology 58:72, 1983.
188.
Thornton C, Catley DM, Jordan C, et al: Enflurane
anaesthesia causes graded changes in the brainstem and early cortical auditory evoked
response in man. Br J Anaesth 55:479, 1983.
189.
Thornton C, Heneghan CPH, James MFM, et al: Effects
of halothane or enflurane with controlled ventilation on auditory evoked potentials.
Br J Anaesth 56:315, 1984.
190.
Thornton C, Heneghan CPH, Navaratnarajah M, et
al: Effect of etomidate on the auditory evoked response in man. Br J Anaesth 57:554,
1985.
191.
Thornton C, Heneghan CPH, Navaratnarajah M, et
al: Selective effect of Althesin on the auditory evoked response in man. Br J Anaesth
58:422, 1986.
192.
Heneghan CPH, Thornton C, Navaratnarajah M, et
al: Effect of isoflurane on the auditory evoked response in man. Br J Anaesth 59:277,
1987.
193.
Thornton C, Konieczko K, Jones JG, et al: Effect
of surgical stimulation on the auditory evoked response. Br J Anaesth 60:372, 1988.
194.
Thornton C, Barrowcliffe MP, Konieczko KM et al:
The auditory evoked response as an indicator of awareness. Br J Anaesth 63:113,
1989.
195.
Newton DEF, Thornton C, Konieczko K, et al: Auditory
evoked response and awareness: A study in volunteers at sub-MAC concentrations of
isoflurane. Br J Anaesth 69:122, 1992.
196.
Schwender D, Rimkus T, Haessler R, et al: Effect
of increasing doses of alfentanil, fentanyl and morphine on mid-latency auditory
evoked potentials. Br J Anaesth 71:622, 1993.
197.
Iselin-Chaves IA, Moalem HE, Gan TG, et al: Changes
in the auditory evoked potentials and the bispectral index following propofol or
propofol and alfentanil. Anesthesiology 92:1300, 2000.
198.
Mantzaridis H, Kenny GH: Auditory evoked potential
index: A quantitative measure of changes in auditory evoked potentials during general
anesthesia. Anaesthesia 52:1030, 1997.
199.
Jensen EW, Nygaard M, Hennenberg SW: On-line
analysis of middle latency auditory evoked potentials (MLAEP) for monitoring depth
of anesthesia in laboratory rats. Med Eng Phys 20:722, 1998.
200.
Struys MMRF, Jensen EW, Smith W, et al: Performance
of the ARX-derived auditory evoked potential index as an indicator of anesthetic
depth. Anesthesiology 96:803, 2002.
201.
Schmidt GN, Bischoff P, Standl T, et al: ARX-derived
auditory evoked potential index and bispectral index during the induction of anesthesia
with propofol and remifentanil. Anesth Analg 97:139, 2003.